Intracranial Hypertension in Patients with Hemorrhagic Cerebrovascular Disease Diagnosed by Ocular Globe Ultrasonography in a Second-Level Hospital in Mexico
Main Article Content
Abstract
Introduction: Intracranial hypertension (ICH) is a serious complication characterized by increased pressure within the cranial cavity. Non-invasive techniques such as optic nerve sheath diameter (ONSD) measurement, the ONSD/transverse ocular diameter ratio (ONSD/TOD), and optic disc elevation (ODE) allow rapid, safe, bedside detection, facilitating timely diagnosis.
Problem statement: Cranial computed tomography and invasive intracranial pressure monitoring are the reference diagnostic methods; however, their availability is limited in second-level hospitals. Therefore, this study proposes ocular globe ultrasonography as a non-invasive alternative to identify intracranial hypertension and support therapeutic decision-making.
Objective: To evaluate the presence of intracranial hypertension in patients with hemorrhagic cerebrovascular disease using ocular globe ultrasonography in a second-level hospital.
Materials and methods: A prospective, analytical, cross-sectional study was conducted in 98 patients, 72 of whom were diagnosed in the Internal Medicine Department of the Hospital General Regional de Orizaba, Veracruz, between December 2024 and June 2025. ONSD, ONSD/TOD, and ODE were measured, and data were analyzed to determine sensitivity, specificity, positive predictive value, negative predictive value, and ROC curves.
Results: Of the 98 patients included, 72 were diagnosed by computed tomography. Intracranial hypertension was identified using ONSD in 69 patients (95.8%), while 3 patients (4.2%) showed no evidence. Sensitivity was 95.8% and specificity 84.6%. The ONSD/transverse ocular diameter ratio detected intracranial hypertension in 65 patients (90.3%) and absence in 7 patients (9.7%), with a sensitivity of 90.3% and specificity of 76.9%. Optic disc elevation was observed in 60 patients (83.3%), while 12 patients (16.7%) showed no alteration, with a sensitivity of 83.3% and specificity of 80.8%. The receiver operating characteristic curve for the three measurements showed an AUC of 0.95 (95% CI), compared with an AUC of 0.93 for ONSD alone.
Conclusions: The combination of ONSD, ONSD/TOD, and ODE provides greater sensitivity and specificity for detecting intracranial hypertension compared with the isolated use of ONSD, consolidating these parameters as useful tools for non-invasive neuromonitoring.
Article Details

This work is licensed under a Creative Commons Attribution 4.0 International License.
References
I. Jose C, Martha C, Parmenides G, Enfermedad Vascular Cerebral Isquemica: revisión extensa de la bibliografía para el medico de primer contacto. Artículo de revisión de Revista Medicina interna. 2020 enero-febrero;35.
https://doi.org/10.24245/minv35i1.2212
II. Seda G, Gokhan Y, Merva T, Mukerrem A, Mustafa O, Measuring the Optic Nerve Sheath Diameter with Ultrasound in Acute Middle Cerebral Artery Stroke Patients. Journal of Stroke and Cerebrovascular Diseases, Vol. 30, No. 2 (February), 2021: 105523
III. Seong-Joon L, et al. Optic nerve sheath diameter change in prediction of malignant cerebral edema in ischemic stroke: an observational study. Lee et al. BMC Neurology (2020) 20:354 ttps://doi.org/10.1186/s12883-020-01931-w
IV. Javad S, et al. Association of optic nerve sheath diameter in ocular ultrasound with prognosis in patients presenting with acute stroke symptoms. Turkish Journal of Emergency Medicine 19 (2020) 132–135 https://doi.org/10.1016/j.tjem.2019.07.001
V. Rohit P, et al. Ultrasound of Optic Nerve Sheath Diameter and Stroke Outcomes. Critical Care Explorations. November 2021, Volume 3 Number 11. DOI: 10.1097/CCE.0000000000000565
VI. Ángel A, et al. Neuromonitoreo ultrasonográfico en el periopertatorio: diamtro de vaina de nervio óptico y Doppler transcraneal, Cirugía y cirujanos 2020;87, DOI:10.24875/CIRU.18000501
VII. Jorge R, et al. Correlation between optic nerve sheath diameter and extracorporeal life support time. Anales de Pediatría 96 (2022) 91-96
VIII. Suresh V. Optic nerve sheath diameter guided detection of sepsis-associated encephalopathy. Suresh Critical Care, 2020; Vol (24): 1-2 https://doi.org/10.1186/s13054-020-03232-7
IX. Carvajal L, Vargas R, Hidalgo S. Carpio, Leopoldo Carvajal. «Fisiopatología del síndrome de hipertensión intracraneal. Revista Médica Sinergia, 2021; Vol. 6(10): 1-9
X. Maddalena De B, A-scan ultrasonography and optic nerve sheath diameter assessment during acute elevations in intra abdominal pressure. Surgery. El Servier 2019; 167: 478-483.
XI. Abhinav R, Barry M, Aaron, S. Lord, Management of Elevated Intracranial Pressure: a Review. Curr Neurol Neurosci Rep 19, 99 (2019). https://doi.org/10.1007/s11910-019-1010-3
XII. Lochner, P., Czosnyka, M., Naldi, A. et al. Optic nerve sheath diameter: present and future perspectives for neurologists and critical care physicians. Neurol Sci 40, 2447–2457 (2019). https://doi.org/10.1007/s10072-019-04015-x
XIII. Raoul R, et al. Optic nerve sheath diameter assessment by neurosonology: A review of methodologic discrepancias. Received: 23 May 2021 Revised: 22 June 2021
DOI: 10.1111/jon.12906
XIV. Arnab Banerjee, Richa Aggarwal, Kapil dev Soni, Anjan Tirkha, Increase in optic nerve sheath diameter predicts early cerebral involvement in fat embolism syndrome, Chinese Journal of Traumatology, Volume 24, Issue 3, 2021, Pages 180-182, ISSN 1008-1275,
https://doi.org/10.1016/j.cjtee.2021.02.004.
XV. Bruce C, et al. Ischaemic stroke, Nature reviews, disease primers, 2019. 5:70